{"id":1202,"date":"2016-07-27T21:53:11","date_gmt":"2016-07-27T21:53:11","guid":{"rendered":"https:\/\/wireless-telemetry.com\/blog\/?p=1202"},"modified":"2016-07-27T21:53:11","modified_gmt":"2016-07-27T21:53:11","slug":"passive-ventilation-for-outdoor-rtu-control-enclosures","status":"publish","type":"post","link":"https:\/\/wireless-telemetry.com\/blog\/?p=1202","title":{"rendered":"RTU Enclosure Heat Reduction with Passive or Active Ventilation"},"content":{"rendered":"<h3><strong>RTU Enclosures Can Trap Heat During Summer Months<\/strong><\/h3>\n<div id=\"attachment_1843\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1843\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2023\/06\/Jim_Mimlitz_Newsletter-150x150.jpg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2023\/06\/Jim_Mimlitz_Newsletter.jpg 2x\" alt=\"admin\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-1843\" class=\"wp-caption-text\">Jim Mimlitz, NRI<\/p><\/div>\n<p>During the summer months, the internal air temperature of outdoor-installed RTU Enclosures can become very hot\u00a0\u2014 especially at locations where the enclosure is subject to direct sunlight. \u00a0And while the RTU electronics are industrial-rated, and designed to withstand extreme temperatures, the longevity of the equipment can be improved by reducing the extreme air temperatures within the enclosure.<\/p>\n<p>Protection against extreme cold (freezing) and condensation is provided through an internal convection or strip heater. \u00a0However, the purpose of this article is to address handling the other temperature extreme: HEAT.<\/p>\n<p>There are several available methods to reduce heat inside an RTU enclosure:<\/p>\n<ol>\n<li>Build a Roof Structure to Shade Against Direct Sunlight<\/li>\n<li>Installation of an Enclosure Air Conditioning Unit<\/li>\n<li>Active Ventilation (Forced Air Flow with Electric Fan)<\/li>\n<li>Passive Ventilation (Free Air Flow)<\/li>\n<\/ol>\n<p>Option 1, building a roof structure to shade the enclosure, is always a nice option. \u00a0It also provides the additional benefit of protecting the enclosure against rain\/sleet\/snow.<\/p>\n<p>Option 2, installation of an enclosure air conditioning unit, is overkill for the typical RTU enclosure. \u00a0This option is generally reserved for larger VFD enclosures that internally generate a significant amount of heat. \u00a0The cost of entry-level air conditioning units for industrial enclosures generally exceed $1000 plus installation.<\/p>\n<p>Option 3, active ventilation with a forced air flow fan, is an extremely cost-effective option. \u00a0The <strong>Stego No.\u00a0018000-02<\/strong> is an excellent model for small RTU enclosures. \u00a0It is available from <a href=\"http:\/\/automationdirect.com\">AutomationDirect.com<\/a>, and is a shelf-stocked item here at Navionics Research Inc. \u00a0By default, this unit pulls outside air into the enclosure, although its direction can be easily reversed.<\/p>\n<p>Option 4, passive free-flow ventilation, is the simplest, cost-effective option. \u00a0The <strong>Stego No.\u00a0118000-00<\/strong> is an excellent model for small RTU enclosures. \u00a0It is also available from <a href=\"http:\/\/automationdirect.com\">AutomationDirect.com<\/a>, and is also a shelf-stocked item here at Navionics Research Inc.<\/p>\n<p>When providing either active or passive ventilation, it is important to provide a second passive vent in the enclosure to allow for discharge air flow.<\/p>\n<div id=\"attachment_1210\" style=\"width: 310px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1210\" class=\"size-medium wp-image-1210\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Active_Stego_001-300x245.jpg\" alt=\"Active Fan Ventilation: Stego No. 018000-02\" width=\"300\" height=\"245\" \/><p id=\"caption-attachment-1210\" class=\"wp-caption-text\">Active Fan Ventilation: Stego No. 018000-02<\/p><\/div>\n<div id=\"attachment_1211\" style=\"width: 267px\" class=\"wp-caption alignleft\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1211\" class=\"size-medium wp-image-1211\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Passive_Stego_001-257x300.jpg\" alt=\"Passive Ventilation: Stego No. 118000-00\" width=\"257\" height=\"300\" \/><p id=\"caption-attachment-1211\" class=\"wp-caption-text\">Passive Ventilation: Stego No. 118000-00<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h3><strong>Field-Installation of Passive Ventilation Into an RTU Enclosure<\/strong><\/h3>\n<p>At a municipal water district in rural Illinois, the legacy RTU enclosure at the elevated tank was experiencing high internal temperatures, due to direct sunshine on the enclosure outer walls. \u00a0To provide relief, the water district constructed a roof structure to shield against direct sunlight, and also commissioned the installation of passive ventilation.<\/p>\n<p>The following photos illustrate the finished installation. \u00a0Please note that any such field-modification may change the NEMA rating of an enclosure. \u00a0For details, refer to the specifications of the ventilation device and\/or the enclosure itself.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1220\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1726s-300x225.jpg\" alt=\"Img_1726s\" width=\"300\" height=\"225\" \/>\u00a0\u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1218\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1727s-300x225.jpg\" alt=\"Img_1727s\" width=\"300\" height=\"225\" \/><\/p>\n<h5><strong>Two (2) Stego 118000-00 vents were installed. Note that the vents were installed on opposing sides of the enclosure, and at different elevations, which will foster increased horizontal cross-flow and vertical convective-flow.<\/strong><\/h5>\n<p>The following photos illustrate the installation process for one of the two vents:<\/p>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1233\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1233\" class=\"size-medium wp-image-1233\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1684s-225x300.jpg\" alt=\"Mark Corners For Cutout, and Holes For (Optional) Mounting Screws.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1233\" class=\"wp-caption-text\">Mark Corners For Cutout, and Holes For (Optional) Mounting Screws. A Paper Template Is Provided With The Kit, Although We Have Constructed a PlexiGlass Template For Our In-House Use.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1234\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1234\" class=\"size-medium wp-image-1234\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1685s-225x300.jpg\" alt=\"Use Straight Edge To Mark Cutout Boundary.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1234\" class=\"wp-caption-text\">Use Straight Edge To Mark Cutout Boundaries.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1235\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1235\" class=\"size-medium wp-image-1235\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1686s-225x300.jpg\" alt=\"Mark Holes For (Optional) Mounting Screws.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1235\" class=\"wp-caption-text\">Mark Holes For (Optional) Mounting Screws.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1236\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1236\" class=\"size-medium wp-image-1236\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1689s-225x300.jpg\" alt=\"Apply Duct Tape To Border To Protect Enclosure Painted Surface During Jigsaw Cutting.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1236\" class=\"wp-caption-text\">Apply Duct Tape To Border To Protect The Enclosure&#8217;s Painted Surfaces From Being Scratched During Jigsaw Cutting.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1237\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1237\" class=\"size-medium wp-image-1237\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1690s-225x300.jpg\" alt=\"Drill Four 3\/8 Inch Starter Holes For Jigsaw.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1237\" class=\"wp-caption-text\">Drill Four (4) Starter Holes For Jigsaw. \u00a03\/8 Inch Holes Accommodate Most Standard Jigsaw Blades.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1238\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1238\" class=\"size-medium wp-image-1238\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1693s-225x300.jpg\" alt=\"Use Metal-Cutting Jigsaw To Cut Square Boundary.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1238\" class=\"wp-caption-text\">Use A Jigsaw (With Metal-Cutting Blade) To Cut The Square Boundary.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1224\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1224\" class=\"size-medium wp-image-1224\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1703s-225x300.jpg\" alt=\"Remove Duct Tape.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1224\" class=\"wp-caption-text\">Remove Protective Duct Tape.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1225\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1225\" class=\"size-medium wp-image-1225\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1705s-225x300.jpg\" alt=\"Smooth the Edges With a Metal File.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1225\" class=\"wp-caption-text\">Smooth and Deburr the Edges With a Metal File.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1226\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1226\" class=\"size-medium wp-image-1226\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1707s-225x300.jpg\" alt=\"Drill Starter Holes For the Four Mounting Sheet Metal Screws (Optional). A 1\/8 Inch Bit Was Used.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1226\" class=\"wp-caption-text\">Drill Starter Holes For the Four Mounting Sheet Metal Screws (Optional). A 1\/8 Inch Bit Was Used.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1232\" style=\"width: 310px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1232\" class=\"size-medium wp-image-1232\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1725s-300x225.jpg\" alt=\"Clean Out Metal Shavings With Mini Vacuum.\" width=\"300\" height=\"225\" \/><p id=\"caption-attachment-1232\" class=\"wp-caption-text\">Clean Out Metal Shavings With Mini Vacuum.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1227\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1227\" class=\"size-medium wp-image-1227\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1709s-225x300.jpg\" alt=\"Remove The Protective Paper From the Ventilation Base's Adhesive Backing.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1227\" class=\"wp-caption-text\">Remove The Protective Paper From the Ventilation Base&#8217;s Adhesive Backing.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1228\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1228\" class=\"size-medium wp-image-1228\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1711s-225x300.jpg\" alt=\"Attach The Vent Base To The Enclosure Wall, and Secure with Provided Sheet Metal Screws (4).\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1228\" class=\"wp-caption-text\">Attach The Vent Base To The Enclosure Wall, and Secure with Provided Sheet Metal Screws (4).<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1229\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1229\" class=\"size-medium wp-image-1229\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1715s-225x300.jpg\" alt=\"Attach The Filter Media Holder and Filter. Secure Using Provided Plastic Thread-Rolling Screws.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1229\" class=\"wp-caption-text\">Attach The Filter Media Holder and Filter. Secure Using Provided Plastic Thread-Rolling Screws. Note that the Filter Media is Fine Enough To Prevent Bugs From Entering, But Coarse Enough To Allow Air Flow.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1230\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1230\" class=\"size-medium wp-image-1230\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1717s-225x300.jpg\" alt=\"Attach and Secure The Louvered Vent Cover.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1230\" class=\"wp-caption-text\">Attach and Secure The Louvered Vent Cover.<\/p><\/div>\n<p>&nbsp;<\/p>\n<div id=\"attachment_1231\" style=\"width: 235px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1231\" class=\"size-medium wp-image-1231\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Img_1723s-225x300.jpg\" alt=\"Inside View of the Completed Vent.\" width=\"225\" height=\"300\" \/><p id=\"caption-attachment-1231\" class=\"wp-caption-text\">Inside View of the Completed Vent.<\/p><\/div>\n<p>Telemetry System historical trends were analyzed before and after the vent installation, and the data validated the successful temperature reduction:<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Before Ventilation System Installed<\/strong><\/span><br \/>\n<strong>7-24-2016, 5:00pm<\/strong><br \/>\nOutside Air Temperature: 96.8 degF<br \/>\nEnclosure Inside Air Temperature: 116.9 degF<br \/>\n<span style=\"color: #ff0000;\"><strong>Inside Minus Outside Temp Differential: +20.1 degF<\/strong><\/span><\/p>\n<p><span style=\"text-decoration: underline;\"><strong>After Ventilation System Installed<\/strong><\/span><br \/>\n7-27-2016, 4:00pm<br \/>\nOutside Air Temperature: 89.6 degF<br \/>\nEnclosure Inside Air Temperature: 101.8 degF<br \/>\n<span style=\"color: #00ccff;\"><strong>Inside Minus Outside Temp Differential: 12.2 degF<\/strong><\/span><\/p>\n<p>Without the ventilation, the enclosure temperature had been observed to be around 20 degF higher than ambient. \u00a0With the ventilation, the enclosure temperature had been observed to be around 12 degF higher than ambient. \u00a0It would also be expected that active, fan-based ventilation would result in an even lower temperature differential.<\/p>\n<h3><strong>RTU Enclosures Installed In Non-Temperature-Controlled Buildings<\/strong><\/h3>\n<p>RTU Enclosures that are installed inside a non-air-conditioned building can also result in extreme temperatures inside industrial enclosures. \u00a0In these situations, the building can trap heat and become very warm, and the enclosure further traps its internally-generated heat, therefore becoming even hotter than the already-warm building. \u00a0Furthermore, inside a non-air-conditioned building, there is no air movement to aid in cooling. \u00a0In these situations, we highly recommend using an electric fan-based vent system, such as the <strong>Stego No.\u00a0018000-02<\/strong>.<\/p>\n<h3><strong>Thermostat-Control of Active Ventilation<\/strong><\/h3>\n<p>When using an electric fan-based ventilation system, logic-control, or thermostat-control is highly recommended. \u00a0Temperature-based logic or the thermostat will ensure that the fan is only used on an as-needed basis, increasing the longevity of the fan&#8217;s moving parts. \u00a0An example of a cooling thermostat (normally-open, close-on-temp-rise) is the <strong>Stego No.\u00a0011419-00<\/strong> din-rail-mount thermostat. \u00a0It is available from <a href=\"http:\/\/automationdirect.com\">AutomationDirect.com<\/a>, and is a shelf-stocked item here at Navionics Research Inc.<\/p>\n<div id=\"attachment_1248\" style=\"width: 245px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1248\" class=\"size-medium wp-image-1248\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/07\/Stego_Cooling_Thermostat_02-235x300.jpg\" alt=\"Stego No. 011419-00 Cooling Thermostat\" width=\"235\" height=\"300\" \/><p id=\"caption-attachment-1248\" class=\"wp-caption-text\">Stego No. 011419-00 Cooling Thermostat<\/p><\/div>\n<h3><strong>Winterizing the Ventilation System<\/strong><\/h3>\n<p>During winter months, we recommend closing off the vents, so that energy from the internal enclosure heater is not vented to atmosphere and wasted.<\/p>\n<h3><strong>Enclosure Heat Reduction Extends Component Life<\/strong><\/h3>\n<p>Do you have an industrial enclosure that runs too\u00a0hot in the summer? \u00a0Passive or active ventilation can extend the life of the internal components by reducing the high temperature extremes. \u00a0Give us a call, and\u00a0we&#8217;ll get started.<\/p>\n<p>And as always, if you have any questions, please don&#8217;t hesitate to reach out by phone or email.<\/p>\n<p><strong>Telemetry, SCADA, &amp; Controls Newsletter<\/strong><\/p>\n<p>Was this article helpful?\u00a0 Would you be interested in receiving updates such as these in our occasional email-delivered newsletter?\u00a0 If so, here&#8217;s our sign-up page:<\/p>\n<p><a href=\"https:\/\/www.wireless-telemetry.com\/signup\/signup.htm\">Subscribe to\u00a0Navionics Research&#8217;s\u00a0&#8220;Telemetry, SCADA, &amp; Controls Newsletter&#8221;<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>RTU Enclosures Can Trap Heat During Summer Months During the summer months, the internal air temperature of outdoor-installed RTU Enclosures can become very hot\u00a0\u2014 especially at locations where the enclosure is subject to direct sunlight. \u00a0And while the RTU electronics are industrial-rated, and designed to withstand extreme temperatures, the longevity of the equipment can be <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/wireless-telemetry.com\/blog\/?p=1202\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":1211,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,15],"tags":[57,147,161],"class_list":["post-1202","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-applications","category-rtu","tag-enclosure-ventilation","tag-temperature-control","tag-ventilation"],"_links":{"self":[{"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1202","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1202"}],"version-history":[{"count":0,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1202\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/"}],"wp:attachment":[{"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1202"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1202"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1202"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}