{"id":1339,"date":"2016-10-04T01:21:34","date_gmt":"2016-10-04T01:21:34","guid":{"rendered":"https:\/\/wireless-telemetry.com\/blog\/?p=1339"},"modified":"2016-10-04T01:21:34","modified_gmt":"2016-10-04T01:21:34","slug":"multi-monitor-technology-applied-to-a-scada-system","status":"publish","type":"post","link":"https:\/\/wireless-telemetry.com\/blog\/?p=1339","title":{"rendered":"Adding Multiple Monitors to Your SCADA System"},"content":{"rendered":"<div id=\"attachment_1843\" style=\"width: 160px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1843\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2023\/06\/Jim_Mimlitz_Newsletter-150x150.jpg\" width=\"150\" height=\"150\" data-srcset=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2023\/06\/Jim_Mimlitz_Newsletter.jpg 2x\" alt=\"admin\" class=\"avatar avatar-150 wp-user-avatar wp-user-avatar-150 photo\" \/><p id=\"caption-attachment-1843\" class=\"wp-caption-text\">Jim Mimlitz, NRI<\/p><\/div>\n<p>One of the benefits of a well-designed SCADA System is the wealth of data that is made available to the Water Utility operator. Data is presented in the form of realtime graphical displays, historical trend charts, and alarm displays. However, the large amount of data has created a new problem: How to fit it all on one screen?<\/p>\n<p>Certainly, the most important data can be displayed on the SCADA program&#8217;s main display, and the additional data can be made available by drilling down into detailed windows. But what if the most important data points are too numerous to fit on the main display?<\/p>\n<p>One option is to install a virtual multi-desktop utility, such as <strong><a href=\"https:\/\/technet.microsoft.com\/en-us\/sysinternals\/cc817881\">Desktops<\/a><\/strong> (by <a href=\"http:\/\/www.sysinternals.com\">www.sysinternals.com<\/a>). However, this option requires the operator to work the computer mouse and keyboard to retrieve the data, while in turn suppressing the view of other data.<\/p>\n<h3><strong>Multi-Monitor SCADA System<\/strong><\/h3>\n<p>The most convenient option \u2014 one that requires no operator interface intervention \u2014\u00a0is the addition of <em><strong>multiple computer monitors<\/strong><\/em> to increase the amount of visible data. Multiple monitors is a technology that is well-supported under Microsoft Windows, assuming that the computer is outfitted with a capable graphics adapter, and sufficient RAM and microprocessor speed.<\/p>\n<p>Several NRI SCADA clients have installed dual-monitor capability \u2014\u00a0with one monitor dedicated to a realtime system overview, and the other monitor dedicated to live historical trending charts.<\/p>\n<div id=\"attachment_1363\" style=\"width: 590px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/IMG_2331.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1363\" class=\"size-large wp-image-1363\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/IMG_2331-1024x576.jpg\" alt=\"Dual-Monitor SCADA System at a Rural Water District\" width=\"580\" height=\"326\" \/><\/a><p id=\"caption-attachment-1363\" class=\"wp-caption-text\"><strong>Dual-Monitor SCADA System at a Rural Water District.<\/strong><\/p><\/div>\n<p>Another NRI SCADA client has 4 installed monitors\u00a0\u2014\u00a0with two 60 inch large-screen displays dedicated to a realtime system overview, and two 30 inch displays dedicated to live historical trending charts.<\/p>\n<div id=\"attachment_1364\" style=\"width: 590px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/IMG_2571.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1364\" class=\"size-large wp-image-1364\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/IMG_2571-1024x768.jpg\" alt=\"Quad-Monitor SCADA System at a Regional Water District.\" width=\"580\" height=\"435\" \/><\/a><p id=\"caption-attachment-1364\" class=\"wp-caption-text\"><strong>Quad-Monitor SCADA System at a Regional Water District.<\/strong><\/p><\/div>\n<p>Although the complexity of a multi-monitor system may appear daunting, we are able to lend our knowledge and experience to ensure that the common pitfalls are avoided during installation and setup. \u00a0In fact, the physical installations of our dual-monitor systems were performed by the clients following our instructions; while the software configuration was performed remotely via a secure Remote Service Tunnel.<\/p>\n<div id=\"attachment_1365\" style=\"width: 590px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/IMG_2569.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1365\" class=\"size-large wp-image-1365\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/IMG_2569-1024x768.jpg\" alt=\"Quad-DisplayPort Graphics Adapter, with Quad Active DisplayPort-to-HDMI Adapters\" width=\"580\" height=\"435\" \/><\/a><p id=\"caption-attachment-1365\" class=\"wp-caption-text\"><strong>Quad-DisplayPort Graphics Adapter, with Quad Active DisplayPort-to-HDMI Adapters<\/strong>.<\/p><\/div>\n<div id=\"attachment_1366\" style=\"width: 590px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/IMG_2567.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1366\" class=\"size-large wp-image-1366\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/IMG_2567-1024x768.jpg\" alt=\"Premium HDMI Cable + Inline HDMI Signal Amplifiers Increases Reliability of Long HDMI Cable Runs.\" width=\"580\" height=\"435\" \/><\/a><p id=\"caption-attachment-1366\" class=\"wp-caption-text\"><strong>Premium HDMI Cable + Inline HDMI Signal Amplifiers Increases Reliability of Long HDMI Cable Runs.<\/strong><\/p><\/div>\n<p>&nbsp;<\/p>\n<h3><strong>Quad-Monitor Systems:<\/strong><\/h3>\n<ol>\n<li>AMD FirePro W7000-series Graphics Adapters<\/li>\n<li>Configuration using AMD Control Panel<\/li>\n<li>Quad DisplayPort Output Ports<\/li>\n<li>HDMI Displays<\/li>\n<li>Use Active DisplayPort-HDMI Adapters<\/li>\n<li>Use HDMI Amplifier(s) for Long HDMI Cable Runs<\/li>\n<\/ol>\n<div id=\"attachment_1367\" style=\"width: 370px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/AMD-FirePro-W7000-360W.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1367\" class=\"size-full wp-image-1367\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/AMD-FirePro-W7000-360W.png\" alt=\"AMD FirePro W7000 Professional Graphics Adapter with Four DisplayPort Outputs.\" width=\"360\" height=\"268\" \/><\/a><p id=\"caption-attachment-1367\" class=\"wp-caption-text\"><strong>AMD FirePro W7000 Professional Graphics Adapter with Four DisplayPort Outputs.<\/strong><\/p><\/div>\n<h3><strong>Dual-Monitor Systems:<\/strong><\/h3>\n<ol>\n<li>AMD FirePro 2270<\/li>\n<li>Configuration using Windows or AMD Control Panel<\/li>\n<li>Single DMS-59 Output Port \u2014 Can Be Split Into Two DVI Ports<\/li>\n<li>Use\u00a0Splitter Cable: DMS-59 to Dual-DVI<\/li>\n<li>Most Aesthetically-Pleasing If Both Monitors Identical.<\/li>\n<\/ol>\n<div id=\"attachment_1368\" style=\"width: 370px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/amd-firepro-professional-graphics-solution-2270.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1368\" class=\"size-full wp-image-1368\" src=\"https:\/\/wireless-telemetry.com\/blog\/wp-content\/uploads\/2016\/10\/amd-firepro-professional-graphics-solution-2270.png\" alt=\"AMD FirePro 2270 Graphics Adapter.\" width=\"360\" height=\"243\" \/><\/a><p id=\"caption-attachment-1368\" class=\"wp-caption-text\"><strong>AMD FirePro 2270 Professional Graphics Adapter with DMS-59 (Dual DVI) Output.<\/strong><\/p><\/div>\n<h3><strong>Additional Resources:<\/strong><\/h3>\n<ol>\n<li><a href=\"http:\/\/www.pcworld.com\/author\/Sarah-Jacobsson-Purewal\/\">http:\/\/www.pcworld.com\/author\/Sarah-Jacobsson-Purewal\/<\/a><\/li>\n<li><a href=\"http:\/\/www.pcworld.com\/article\/2923941\/how-to-create-an-insane-multiple-monitor-setup-with-three-four-or-more-displays.html\">http:\/\/www.pcworld.com\/article\/2923941\/how-to-create-an-insane-multiple-monitor-setup-with-three-four-or-more-displays.html<\/a><\/li>\n<li><a href=\"http:\/\/www.dcables.net\/dvi-faq.aspx\">http:\/\/www.dcables.net\/dvi-faq.aspx<\/a><\/li>\n<li><a href=\"http:\/\/www.asus.com\/support\/faq\/1003223\/\">http:\/\/www.asus.com\/support\/faq\/1003223\/<\/a><\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p>To learn more about how our exciting Multi-Monitor SCADA Technology can increase the ease of monitoring your Water Utility, give us a call, and we&#8217;ll be glad to discuss the details!<\/p>\n<p><strong>Telemetry, SCADA, &amp; Controls Newsletter<\/strong><\/p>\n<p>Was this article helpful?\u00a0 Would you be interested in receiving updates such as these in our occasional email-delivered newsletter?\u00a0 If so, here&#8217;s our sign-up page:<\/p>\n<p><a href=\"https:\/\/www.wireless-telemetry.com\/signup\/signup.htm\">Subscribe to\u00a0Navionics Research&#8217;s\u00a0&#8220;Telemetry, SCADA, &amp; Controls Newsletter&#8221;<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>One of the benefits of a well-designed SCADA System is the wealth of data that is made available to the Water Utility operator. Data is presented in the form of realtime graphical displays, historical trend charts, and alarm displays. However, the large amount of data has created a new problem: How to fit it all <span class=\"ellipsis\">&hellip;<\/span> <span class=\"more-link-wrap\"><a href=\"https:\/\/wireless-telemetry.com\/blog\/?p=1339\" class=\"more-link\"><span>Read More &rarr;<\/span><\/a><\/span><\/p>\n","protected":false},"author":1,"featured_media":1363,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7,8,10],"tags":[51,94,115],"class_list":["post-1339","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general","category-historical-trending","category-interface","tag-dual-monitor","tag-multi-monitor","tag-quad-monitor"],"_links":{"self":[{"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1339","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1339"}],"version-history":[{"count":0,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/wp\/v2\/posts\/1339\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=\/"}],"wp:attachment":[{"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1339"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1339"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wireless-telemetry.com\/blog\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1339"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}